Qualcomm GSP-1620 Especificaciones Pagina 129

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 261
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 128
Integrator’s Reference Manual
6-24 80-99208-1 Rev. D
Results Returned
Basic S-Registers
This section defines the basic S-registers for the modem and
the functionality provided by each. Table 6-4 lists the result
codes common to all recognized S-register commands.
Results Returned
Result Code Condition
CONNECT The command was correctly recognized and
processed and the transition from
Online-Command to Online mode was
successful.
NO CARRIER The command was correctly recognized and
processed, but the connection was not
successfully resumed.
ERROR The command was not recognized, the <value>
parameter was out of range or some syntactical
error was encountered.
Table 6-4. Common Result Codes for S-Register Commands
Result Condition
OK The <value> sent was recognized and
supported. <value> is now the new value for
the specified S-register.
ERROR <value> is not recognized. The command is
ignored and the specified S-register is left
unchanged.
<value>
OK
Sx? is used to query S-register x’s current
setting.