J1939 Packet Detection Problem
Problem: J1939 Packet Detection Fails
Ignition must be on for the truck to broadcast/supply vehicle data.
Note
If the Core Data Items test passes (i.e. green check), it’s acceptable for the J1939 Packet
Detection test to fail. It would mean that the MCP50 system is getting its vehicle data from
the J1587 link.
This is determined by the VDS configuration sent to the unit from the Vehicle Data
Configuration (VDC) on the Customer Portal. Contractors and Service Centers should first
contact the customer to verify that the units were configured correctly.
In order to get J1939 data, a truck’s engine must be supplying the J1939 data, a connection
must be made to the J1939 wires (Power/IO cable), and the unit must be configured to look
for the J1939 data. Many old trucks/engines do not transmit J1939 packets.
If packets are not detected, check the connections to the J1939 data link and verify that it is
properly configured.