Qualcomm OBDII J1708 Guía para resolver problemas Pagina 68

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 110
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 67
Normal Performance Performance Monitoring Troubleshooting
24-2 80-JB566-1 Rev. C
MAY CONTAIN U.S. AND INTERNATIONAL EXPORT CONTROLLED INFORMATION
A tag of “0” indicates that the unit has not received it s parameters. Call your company
dispatch administrator and ask for the parameters to be sent. A non-zero tag indicates that
the unit has received parameters.
The Core Data Items test checks for all essential data items for Performance Monitoring.With
ignition in the ON position, review data that is available listed under the System->Diag tab
Core Data Items->Details.
At a minimum, Performance Monitoring needs current data from Speed, EngineRPM, Fuel,
and DistanceLTD. These are checked for when a system verification is run. The core data
items verifies these are received. The screen above shows how the unit is configured, if an
item is detected, and the source address if detected.
If any data items are not present:
Ensure the MCP50 is configured for the right Data Bus using the Vehicle Data Configurator.
If problem persists, contact QES Customer Support at 800-541-7490 for assistance.
J1939 0 0.0 MPH
0.0 %
Off
0.00
21355.31 Miles
3218.94 Gallons
570.90 Hours
0
0
0
0
23
17
J1939
J1939
J1939
J1939
J1939
J1939
Vista de pagina 67